Port Elysium

PORT ELYSIUM

Request Access ← Back to Port Elysium
Utilities · SWAC

Cooled by the Deep Ocean

Port Elysium OpCo 22

About 900 metres down, some 3 km off Stella Maris, seawater stays at about 5–6 °C all year. One deep pipe brings that cold ashore to cool the estate's hotels, farm, apartments, homes, commercial and community buildings, and the marina's shops and food hall, for a fraction of the electricity of conventional air conditioning.

Deep blue ocean water
5–6 °C
Deep seawater at about 900 m, all year
~⅙
The electricity of conventional chillers
One pipe
Carries the estate's whole cooling peak
~7 °C
Chilled water, metered at each building
The vision

The Cleanest Cooling Lies Offshore

Air conditioning is the largest electricity use in Caribbean hotels and homes. Seawater air conditioning (SWAC) draws its cold from the deep ocean instead, using about a sixth of the electricity. It is proven at Bora Bora, Tahiti's hospital and Réunion.

The farm, fish farms and cold stores are anchor customers, and capacity, metered and connection charges make SWAC an income stream in its own right.

How it works

Four Simple Steps

  1. Draw. Cold seawater rises through the deep-water pipe to the shore plant.
  2. Exchange. Heat exchangers pass its cold to the estate's chilled-water loop.
  3. Cool. The network carries chilled water to every connected building and the farm, each metered by its energy valve.
  4. Return. The seawater goes back to depth; the backup chillers stand by.
The most sustainable choice, layer by layer

The Technology

Deep-water pipe

Reaches cold water about 3 km offshore; the used seawater goes back to depth, never into the lagoons.

Heat exchangers

A shore plant passes the ocean's cold to the estate's chilled-water loop.

District cooling network

Chilled water runs to every connected building in insulated pipe laid with the roads, metered at each building.

Chiller backup

A small chiller fleet cools the first buildings, then stands by for the hotels and critical rooms.

Farm cooling

Cold water cools and dries the greenhouse air, and the condensate is reused.

Fish farms and cold stores

Fish tanks and refrigeration plant are cooled by the same cold seawater.

How seawater air conditioning works: deep cold seawater, heat exchangers on shore, and a chilled-water loop to the buildings
Built module by module

Capital Follows Sales

SWAC starts small and grows with the estate. Chiller modules and the network come first, cluster by cluster with the roads, so every building has air conditioning from its first day. When the connected load reaches the build gate, one deep pipe is laid to carry the whole peak, and the chillers stay on as backup.

Delivery

Built and Run by Port Elysium

Equipment is bought direct from whichever country offers the best overall deal, with export credit from that country's agency expected to fund most of the imported equipment.

Go deeper
The full pre-feasibility supporting paper and deck: SWAC and District Cooling · Supporting Paper · SWAC and District Cooling · Deck

Open the Deck